easy // Programmable Relays are ideal where multiple push buttons, relays and timers are used–car washes, automatic doors, lighting, pump control. The easy and MFD-Titan device series stands out with its user-friendly operation and programming, with particular importance being placed on simple circuit. Eaton Moeller EASY Relay. For technical or sales support call the Eaton Electric Automation and Motor Control Experts.

Author: Doular Nishicage
Country: Ecuador
Language: English (Spanish)
Genre: Love
Published (Last): 11 July 2016
Pages: 293
PDF File Size: 14.96 Mb
ePub File Size: 2.32 Mb
ISBN: 805-3-36884-553-9
Downloads: 10278
Price: Free* [*Free Regsitration Required]
Uploader: Shar

Enter an incorrect password 3 times, and the program will be deleted and the password removed and you may then put in a new program.

Figure 24 Figure 25 P-Buttons: Inputs are sometimes subject to “contact bounce” from pushbuttons or other input devices, which may cause a momentary “chatter” in some circuits. Figure 26 “if” Jumps: Figure 29 Figure 30 Figure 31 Password Protection: Shown here is a typical parameter display.

Move one digit to the left and use the UP cursor to change to one of the other types. If the password appears as “XXXX” then a previous password had been set and is stored in memory. Changing or viewing the program. Figure 39 shows a Master unit and a Slave unit mounted side by side, connected by a small plug-connector that is included with the Slave unit.

  COMO FAO PARA UNIR ARQUIVOS EM PDF

Moeller EASY512 Manuals

These are always connected to inputs I7 and I8. Power the easy5512 up, then press the OK button 3 times and you will arrive at the blank screen where you will enter your program.

Note you may use the same input symbol repeatedly. This can make manuwl very handy alternator circuit. This delay is approximately 20 milliseconds. The series units have the ability to “jump” to another section of the program, thereby skipping certain portions.

Q-Relays have auxiliary contacts which can be used in any of the 3 left columns. The various menus can be displayed in any of manua languages: The maximum preset isand maximum count is I3 operates the “reset” coil and causes Q2 to drop out. Use the cursor again to move the line drawing tool to the right, twice. Wiring for Series units with transistor outputs are identical.

Note that the screen is 4 columns wide, which allows for 3 contacts plus one coil on the right.

Moeller EASY Manuals

On models that have the clock, the “WE” on the right indicates “wednesday” and below that is the time of day in 24 hour format. Output Relay Q Contacts: Figure 29 Figure 30 Figure Line Fuse should be minimum 1 Amp slow-blow. Figure 9 Now move down to the 3rd line, and press OK twice to enter I1. This comparator is mznual when the voltage on I8 is greater than or equal to a setpoint value.

  ERNESTINE SADE PDF

Programming instructions for the mini PLC. Shown here is a simple on-delay timer circuit and parameter display.

Klockner Moeller EASY Programming Instructions

After the reset coil RT1 is deactivated, the timer remains dead until the trigger coil TT1 is momentarily deactivated and then reactivated. More specific information appears in the next section below.

The units can be set to “retain” or “remember” the value of various functions thru a power-down and resume running exactly where they left off when powered-up again.

Figure 7 Now use the cursor disk to move to the left, to the 2nd position, right next to the I1 symbol. On-Delay, ” X, “: Figure 8 Now use the cursor to move to the 2nd row, all the way to the left.

This means that the parameter screen for this particular timer is available even when a password is active, and one may change the time values but not the function or type. This is identical to the normal off-delay ” ” function except that the time will be a random number between zero and the preset time.